Engineering & Construction Inspection Department
Site Plan Requirements
All site plans must contain the following information and must be up-to date:
- Street address
- Legal description
- Property Owner
- Zoning
- North arrow
- Plan drawn to useable scale
- Scale indicated
- Size and location of all existing buildings and structures
- Size and location of all easements
- All lot dimensions and building setbacks
- Location and size of proposed new structures/additions.
- Distance to all lot boundaries from existing and proposed structures
- Structure location and layout shall match floor plans
- Location of all driveways and parking
- Limits of disturbance
- Existing and proposed landscaping
- Location and size of permanent LP gas tanks
- Location of all exterior HVAC equipment
- Location of existing adjacent structures
- Location of all utilities
- Basic topography with minimal spot elevations showing drainage patterns
- Tabulation of all existing and proposed impervious areas
Depending on the project, additional information will be required to be shown on the site plan or submitted with the site plan as follows:
- Critical Area Project Application (Over 50% of site)
- Critical Area Project Application (Under 50% of site)
-
Detailed topography and spot elevations
-
Stormwater Management Best Management Practices (BMPs) and calculations
-
Wetland delineations
-
Zoning density calculations
-
Required parking calculations